2
GAS HOB
MODEL ZAF 42
INSTRUCTION BOOKLET
Please read this instruction booklet before using the appliance
Vue de la page 0
1 2 3 4 5 6 ... 17 18

Résumé du contenu

Page 1 - MODEL ZAF 42

2GAS HOBMODEL ZAF 42INSTRUCTION BOOKLETPlease read this instruction booklet before using the appliance

Page 2 - Important Safety Information

11Important safety requirementsThis hob must be installed in accordance with the GasSafety (Installation and Use) Regulations (CurrentEdition) and the

Page 3 - Contents

1255047058050055 min.FO 2109Rectangular cut-out size for hobA) End of shaft with nutB) WasherC) ElbowIt is important to install the elbow correctly,wi

Page 4 - Description of the Hob

13Building InON/OFF SWITCHFLEXOUTLETON/OFF SWITCHFLEXOUTLETFO 0763FO 07643020 min60abFO 1013123Dimensions are given in mm.Building over a cupboard or

Page 5 - Operation

14Electrical connectionsAny electrical work required to install thishob should be carried out by a qualifiedelectrician or competent person, inaccorda

Page 6 - Maintenance and Cleaning

15BLN01234220/240AWiring diagramA. IGNITOR SWITCHB. IGNITOR UNIT

Page 7 - Service and Spare Parts

16Fault FindingPreliminary Electrical Systems CheckA. EARTH CONTINUITY CHECK -Appliance must be electricallydisconnected - meter set on Ω (Ohms) x 1sc

Page 8 - Peace of Mind for 24 Months

17Ignition System / Gas IgnitionYESCheck plug top fuse andreplace if necessaryCheck polarity and earthcontinuity of supply pointCheck earth continuity

Page 9 - Engineer technical data

18CommissioningWhen the hob has been fully installed it will benecessary to check the minimum flame setting. To dothis, follow the procedure below.- T

Page 10 - Important safety requirements

19Conversion from Natural Gas to LPGIt is important to note that this model is designed foruse with natural gas but can be converted for use withbutan

Page 11 - Installation

3Important Safety InformationYou MUST read these warnings carefully before installing or using the hob.If you need assistance, contact our Customer Ca

Page 12 - Building In

4For the UserDescriptionof the Hob Page 5Operation Page 6Maintenanceand Cleaning Page 7Something NotWorking? Page 8Service andSpare Parts Page 8Guaran

Page 13 - Electrical connections

51. Hob Top2. Rapid Burner3. Semi-rapid Burners4. Auxiliary Burner5. Control knob for back right burner (semi-rapid)6. Control knob for back left burn

Page 14 - Wiring diagram

6HOB BURNERSTo light a burner, turn the relevant control knobanticlockwise to maximum position. At the same timepush the electric ignition button whic

Page 15 - Fault Finding

7Before any maintenance or cleaning can becarried out, you must DISCONNECT thehob from the electricity supply.The hob is best cleaned whilst it is sti

Page 16

8Something Not Working? SYMPTOM There is no spark when lighting the gas The gas ring burns unevenly SOLUTION◆ Check that the unit is plugged in

Page 17 - Commissioning

9ZANUSSI GUARANTEE CONDITIONSWe, Zanussi, undertake that if, within 24 months ofthe date of the purchase, this Zanussi appliance orany part thereof is

Page 18

10Ignition HT SparkSpark Generator Ispra Control's BF 50046 - 230-240V 0.6 YA T 120Spark Gap FixedOVERALL DIMENSIONSWidth: 580 mm.Depth: 500