Natural Gas: G20 (2H) 20 mbar
Bypass diameters
BURNER Ø BYPASS 1/100 mm
Auxiliary 29 / 30
Semi-rapid 32
Rapid 42
Triple Crown 67
Oven 54
Grill 59
Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER
kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Triple Crown 4.0 1.8 146
Rapid 3.0 0.72 119
Semi-rapid 2.0 0.43 96
Auxiliary 1.0 0.35 70
Oven 3.6 1.5 126
Grill 2.5 1.6 111
Gas burners for LPG G30 28-30 mbar
BURNER NORMAL POWER
kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Triple Crown 4.0 1.8 101
Rapid 3.0 0.72 88
Semi-rapid 2.0 0.43 71
Auxiliary 1.0 0.35 50
Oven 3.6 1.5 90
Grill 2.5 1.6 80
Gas connection
The gas pipe in the appliance has two endings.
You can connect the gas supply to either one of
them. The pipe that is not used must be
clogged with the pipe closer, which added to
the appliance.
Use a fixed connections or use a flexible
stainless steel pipes in compliance with the
www.zanussi.com 21