Zanussi ZGG96624 Manuel d'utilisateur Page 13

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 12
10 mm
27 mm
27 mm
A
3 mm
A
B
A) supplied seal
B) supplied brackets
CAUTION!
Install the appliance only on a
worktop with flat surface.
Possibilities for insertion
The panel installed below the hob must be easy
to remove and let an easy access in case a
technical assistance intervention is necessary.
Kitchen unit with door
A) Removable panel
B) Space for connections
Kitchen unit with oven
The electrical connection of the hob and the
oven must be installed separately for safety
reasons and to let easy remove oven from the
unit.
Technical information
Hob dimensions
Width 894 mm
Depth 510 mm
Bypass diameters
BURNER Ø BYPASS 1/100 mm
Triple Crown 56
Rapid 42
Semi-rapid 32
Auxiliary 28
Other technical data
TOTAL POWER:
Gas original: G20 (2H) 20 mbar = 13 kW
Gas replacement: G30 (3+) 28-30 mbar = 931 g/h
G31 (3+) 37 mbar = 914 g/h
Electric supply: 230 V ~ 50 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge
fuse
Appliance category: II2H3+
Gas connection: R 1/2"
www.zanussi.com 13
Vue de la page 12
1 2 ... 8 9 10 11 12 13 14 15 16

Commentaires sur ces manuels

Pas de commentaire