Curtains must not be fitted immediately be-
hind the appliance or within 150mm of the
sides of the hotplate. If fitted next to or be-
tween two base units a minimum space of
1mm must be left between each unit and the
sides of the appliance. The hob must be set
to a minimum of 7mm above the adjacent
units. (Note: The levelling feet fitted to the
appliance will achieve a nominal height of
907mm -5+ 13mm. Base units not meeting
the above conditions must be a minimum of
100mm away from the hob.
min 150
min 7
min 1
750
max 400
For appliances installed in the Republic of
Ireland please refer to NSAI-Domestic Gas
Installation IS813 Current Edition Section7
Permitted Locations of appliance Table4---
Locations and Permanent Ventilation re-
quirements-flueless appliances. Note: -
L.P.G. cookers MUST NOT be installed
below ground level i.e. in a basement or
aboard any boat, yacht or other vessel.
Levelling the appliance
Adjustment to suit floor conditions or height
is obtained by rotating clockwise or anti
clockwise the feet at the front and rear of the
appliance. A spirit level should be placed on
one of the shelves to confirm the appliance
is correctly levelled.
Connecting to gas supply
This appliance is designed to be installed
with an appliance flexible connection only.
Supply piping should not be less than R3/8.
Connection is made to the Rc ½ (½" B.S.P)
female threaded entry pipe located just be-
low the hob level on the rear left hand side
of the appliance.
IMPORTANT!
Only liquid sealants to be used when inlet gas
pipe is fitted i.e.: do not use P.T.F.E. sealant
tape.