SOI/TD PR 1/35 599 35 90-23 SERVICE MANUAL DISHWASHERS © ELECTROLUX HOME PRODUCTS ITALY S.p.A. Sp
SOI/TD PR 10/35 599 35 90-23 4.3 Cancelling a programme 4.3.1 Reset To cancel a programme that has already started: 1. Open the door carefully
SOI/TD PR /35 599 35 90-23 114.5 Sequence of operations 1. Press S0 to switch the appliance on. All the LEDs corresponding to the programme/
SOI/TD PR /35 599 35 90-23 125 HYDRAULIC CIRCUIT KEY 1 - Fill hose 11 - Anti-overflow pressure sw
SOI/TD PR /35 599 35 90-23 136 ELECTRICAL COMPONENTS AND THEIR FUNCTIONS 6.1 EDW1100 Electronic control system The EDW1100 control system cons
SOI/TD PR /35 599 35 90-23 14The main circuit board features an EEPROM memory (external to the microprocessor) which stores in memory data relati
SOI/TD PR /35 599 35 90-23 156.3 Power supply and programme selection The main board is powered by the closure of contacts 1-5 and 2-4 of the O
SOI/TD PR /35 599 35 90-23 166.4 Fill circuit 6.4.1 Level and anti-overflow pressure switch • The level of water introduced into the appliance
SOI/TD PR /35 599 35 90-23 176.5 Control of water fill phase The quantity of water necessary to carry out the washing cycle is determined exclus
SOI/TD PR /35 599 35 90-23 186.7 Level stability during washing Once the fill phase has been completed, the cycle proceeds to the washing phas
SOI/TD PR /35 599 35 90-23 196.9 Heating The heating element is enclosed in a protective tube, and is used to heat the washing water (but does n
SOI/TD PR 2/35 599 35 90-23
SOI/TD PR /35 599 35 90-23 206.11 Deactivating the rinse-aid function Introduction of rinse-aid may be deactivated by the user by pressing a comb
SOI/TD PR /35 599 35 90-23 216.13 Regeneration system Regeneration of the softening system, whose duration is approximately 4 minutes, is normal
SOI/TD PR /35 599 35 90-23 226.15 Regeneration levels The counter for execution of the “Ad Hoc” regeneration process is governed by the electron
SOI/TD PR /35 599 35 90-23 236.15.3 Table of regeneration values Number of “end of cycle” LED flashes Water introduced between regeneration cyc
SOI/TD PR /35 599 35 90-23 248 Automatic cycle (only on some models) 8.1 Turbidity sensor Certain models which feature the turbidity sensor may
SOI/TD PR 25/35 599 35 90-23 9 Alarms In the event that an abnormal situation should occur which might affect the correct operation of the a
SOI/TD PR 26/35 599 35 90-23 Type of alarm No. flashes of end-of-cycle LED and “beeps” Displayed to the user Description of the alarm condi
SOI/TD PR 27/35 599 35 90-23 10 Diagnostics mode / Options A single procedure can be used by Service Engineers to access the diagnostics system.
SOI/TD PR 28/35 599 35 90-23 10.3 Cancelling alarm codes from memory / Testing the LEDs It is good practise to cancel the alarm codes: • afte
SOI/TD PR 29/35 599 35 90-23 10.5 Options available to Service Engineers In particular circumstances, i.e. if the user reports unsatisfactory wa
SOI/TD PR 3/35 599 35 90-23 CONTENTS 1 Purpose of this manual...
SOI/TD PR 30/35 599 35 90-23 11 ELECTRICAL FUNCTIONS 11.1 Electrical circuit diagram
SOI/TD PR 31/35 599 35 90-23 11.2 Basic circuit diagram 11.2.1 Key to circuit diagram AR = Orange BI = White B
SOI/TD PR 32/35 599 35 90-23 12 Table of programmes 12.1 60cm Dishwashers The table below lists the phases of the programmes for this type
SOI/TD PR 33/35 599 35 90-23 12.2 45cm Dishwashers The table below lists the phases of the programmes for this type of appliance: 45cm dishw
SOI/TD PR 34/35 599 35 90-23 14 Checking the efficiency of the components In order to facilitate the control procedure for the components to be t
SOI/TD PR /35 599 35 90-23 3515 QUICK GUIDE TO THE SPECIAL FUNCTIONS The table below briefly describes how each of the special functions avai
SOI/TD PR 4/35 599 35 90-23 9.1 Table of alarms ...
SOI/TD PR 5/35 599 35 90-23 1 Purpose of this manual The purpose of this Service Manual is to provide Service Engineers, who already have the b
SOI/TD PR 6/35 599 35 90-23 4 AESTHETIC CHARACTERISTICS: Control panel with the maximum configuration: - VERTICAL Version Con
SOI/TD PR 7/35 599 35 90-23 4.1 CONTROL PANEL 4.1.1 Control panel The configuration of the control panel depends on the following: Number of p
SOI/TD PR 8/35 599 35 90-23 4.1.5 Indicator LEDs The indicator LEDs provide the user with the following information: End of cycle: this LED i
SOI/TD PR 9/35 599 35 90-23 4.2.5 Delayed start To select the delayed-start time: 1. Press button S0 to switch on the appliance. 2. Press a butt
Commentaires sur ces manuels